1. Connect the adjustable and stable DC power supply to AC power:
a、 Set the current knob to the high gear of the current
b、 Adjust the output voltage to the actual voltage value of the tested water pump
2. Place a water pump (submersible pump) in the sink (box) and slowly add clean tap water into the sink until it reaches a height of at least 20cm above the water pump inlet
3. Insert the plastic hose into the water pump outlet, ensuring that the plastic hose is straight and fixed to the horizontal plane
4. Connect the water pump switch in series to the red wire and press the red and black power wires with clips separately on the positive and negative poles of the stabilized power supply (the positive and negative poles of the power wire must not be reversed)
5. Turn the water pump switch to the power-off state, and then connect the red and black power lines with clips to the red (positive) and black (negative) wires of the water pump power line
6. Check the above installation work and confirm that there are no errors
Article source: DC brushless water pump http://www.zsboyang.com
06-01
Reasons for high temperature of DC brushless water pump
The power supply voltage is high, exceeding the additional voltage of the motor by more than 10%, causing an increase in motor iron loss and causing the motor to heat up. DC brushless water pumpIf the
05-12
DC brushless water pump: The advantage of brushless DC pump replacing AC pump
In recent years, DC pumps have become well-known among many companies due to their small size, low power, and high safety factor. Engineers will consider upgrading the original communication pump to a
04-02
DC booster pump: How to choose a water heater booster pump
The booster pump of a water heater is an important accessory in a water heater, and its quality directly affects the quality, brand, and reputation of the water heater. Therefore, when selecting a boo
02-14
DC booster pump: a key task in DC pump management
From the fundamental perspective of handling demands, manufacturers of DC water pumps pursue input-output, which means pursuing the efficiency of DC water pump adoption and operation. From this perspe